100 Foot Ethernet Cable Buying Guide

A 100-foot Ethernet cable is a long-run network cable used to connect devices across a home, office, or small commercial space where Wi-Fi is unreliable or security demands a wired link. The primary trade-off is copper purity and conductor gauge versus cable length: full-copper 23AWG Cat6/Cat6a supports full 100m runs and PoE, while copper-clad aluminum (CCA) and thinner 28-32AWG cables degrade signal and cannot carry PoE safely over distance. The decision rule is simple: buy solid or stranded bare copper in 23-24AWG with a Cat6 or Cat6a rating for any run near or beyond 100 feet, and reject CCA, thin-gauge, or flat/ultra-slim cables for permanent or PoE installations.

Category:Cat5e / Cat6 / Cat6aConductor:Bare copper 23-24AWGPoE Support:802.3af/at/bt (copper only)Jacket Rating:CM / CMR / CMP / CMX

Key takeaways

  • Cat6 handles 1Gbps to 100m and 10Gbps to 55m; Cat6a handles 10Gbps to 100m with stricter shielding and Alien Crosstalk limits.
  • Bare copper 23AWG solid conductors are the standard for in-wall and long runs; 24AWG stranded is acceptable for patch cords but has higher attenuation.
  • CCA (copper-clad aluminum) fails PoE voltage-drop limits and corrodes at terminations; it is not compliant with TIA-568 for horizontal cabling.

At a glance

Price range
Varies by listing
Category
Server Racks, Cooling & Cabling
Last updated
Nov 28, 2026

Current offers

No live listings right now. Search directly on:

Highlights

  • Cat6 handles 1Gbps to 100m and 10Gbps to 55m; Cat6a handles 10Gbps to 100m with stricter shielding and Alien Crosstalk limits.
  • Bare copper 23AWG solid conductors are the standard for in-wall and long runs; 24AWG stranded is acceptable for patch cords but has higher attenuation.
  • CCA (copper-clad aluminum) fails PoE voltage-drop limits and corrodes at terminations; it is not compliant with TIA-568 for horizontal cabling.
  • PoE Type 2 (802.3at) delivers up to 30W at the source but cable resistance over 100 ft causes voltage drop; 23AWG copper keeps drop under ~10% for typical loads.

Best use cases

  • Best fit: running a wired connection from a router to a distant office, garage, or upstairs room — choose Cat6 23AWG solid bare copper with a molded snagless boot and 550MHz rating.
  • Best fit: powering a PoE security camera or access point at 100 ft — choose Cat6 or Cat6a 23AWG bare copper, and confirm the cable is rated for the PoE wattage (802.3af/at) with a 60°C or higher temperature rating.
  • Wrong fit: outdoor burial or permanent in-wall runs using a standard PVC patch cable — skip it; use direct-burial gel-filled or plenum-rated CMR/CMP cable and conduit, or the jacket will crack and moisture will ingress.
  • Wrong fit: tight conduit or under-carpet routing with flat or 32AWG ultra-slim cable — skip it; these have high attenuation and no strain relief, and they cannot carry PoE reliably at 100 ft.

Buying tips

  • For runs at or near 100 ft, stay at 23AWG or 24AWG bare copper; 28-32AWG slim cables are only for short patch runs under 15 ft and low-power devices.
  • Match cable category to speed: Cat5e is fine for 1Gbps to 100m, but Cat6 or Cat6a is required for 2.5G/5G/10G multigig links and future-proofing.
  • Check the PoE budget: a 100 ft 23AWG copper cable drops roughly 1-2V at 1A; a CCA cable can drop 3-5V and cause camera reboots or access-point brownouts.
  • For outdoor or in-wall use, select CMX (outdoor), CMR (riser), or CMP (plenum) jacket ratings; a standard CM patch cable is not code-compliant inside walls or air handlers.

Specs

CategoryCat5e / Cat6 / Cat6a
ConductorBare copper 23-24AWG
PoE Support802.3af/at/bt (copper only)
Jacket RatingCM / CMR / CMP / CMX

Related searches

What to check before buying

  • Measure the actual path length plus 10-15% service loop; a 100 ft cable covers about 85-90 ft of straight run after bends and termination slack.
  • Confirm the device port supports the cable category and speed (e.g., 2.5G port with Cat5e will negotiate 1G only).
  • Verify PoE standard and wattage at the device (802.3af 15.4W, 802.3at 30W, 802.3bt 60-90W) and ensure cable gauge supports the current over 100 ft.
  • Check environmental rating: outdoor cable needs UV-resistant CMX jacket and gel-filled core; plenum spaces require CMP; direct burial requires conduit or burial-rated cable.

FAQ

All Server Racks, Cooling & Cabling buying guides

Data sources: eBay / Amazon listings and product attribute feeds. Updated Nov 28, 2026.