APC AP9562 Buying Guide

The APC AP9562 is a rack-mount power distribution unit (PDU) in APC's Basic Rack PDU line, designed to distribute 15A/120V utility power to multiple IT devices in a standard 19-inch rack. The key trade-off is basic surge-free power distribution versus metered/switched intelligence: Basic PDUs offer no remote monitoring or outlet-level control, but they are the most reliable and lowest-cost way to add outlets without introducing a single point of failure. Buy the AP9562 when you need simple, dense 15A outlet expansion from a single rack circuit; skip it if you require per-outlet switching, current metering, or 208V three-phase input.

Input Plug:NEMA 5-15P (15A/120V)Outlet Count:15 total (12 rear + 3 front)PDU Type:Basic / unmanaged, no meteringRack Form Factor:1U horizontal, 19-inch EIA-310
Typical price range$100.00

Key takeaways

  • 15A maximum input current at 120V nominal, delivering up to 1,800VA total capacity shared across all outlets.
  • 15 total outlets (typically 12 rear and 3 front) in a 1U horizontal rack-mount aluminum chassis for dense equipment power.
  • Basic (non-metered, non-switched) architecture with a single 15A NEMA 5-15P input plug and no network or serial management interface.

At a glance

Category
Server Racks, Cooling & Cabling
Status
Listings available
Last updated
Nov 27, 2026

Current offers

Highlights

  • 15A maximum input current at 120V nominal, delivering up to 1,800VA total capacity shared across all outlets.
  • 15 total outlets (typically 12 rear and 3 front) in a 1U horizontal rack-mount aluminum chassis for dense equipment power.
  • Basic (non-metered, non-switched) architecture with a single 15A NEMA 5-15P input plug and no network or serial management interface.
  • Compatible with standard 19-inch EIA-310 racks and four-post enclosures; includes mounting brackets for tool-less or screw-in installation.

Best use cases

  • Best fit: Small server closets or home labs with a single 15A/120V circuit that need to power 10-15 low-draw devices (switches, routers, NVRs, small servers) from one rack position.
  • Best fit: Rack installations where simple, always-on outlet expansion is required without network dependency—APC Basic PDUs have no firmware, no management card, and no reboot risk.
  • Wrong fit: High-density compute racks with dual-corded servers drawing more than 12A continuous—choose a 20A or 30A PDU (e.g., AP9565/AP9567) or a metered PDU to avoid overloading a 15A circuit.
  • Wrong fit: Remote or branch-office sites requiring outlet-level remote reboot or current monitoring—step up to a switched/metered PDU such as APC AP7922 or AP8858.

Buying tips

  • Confirm your rack circuit is a dedicated 15A/120V branch with a NEMA 5-15R receptacle; the AP9562's 5-15P plug will not fit 20A T-slot (5-20R) or 30A (L5-30R) outlets without an adapter—size the PDU to the circuit, not the other way around.
  • Calculate continuous load at 80% of the 15A rating (12A / 1,440W) and sum device nameplate amps; if your rack exceeds 12A continuous, move to a 20A PDU to avoid nuisance breaker trips.
  • Choose horizontal 1U mounting only when rack depth and rear clearance allow the 15A cord to route without sharp bends; vertical PDUs (e.g., AP9560 series) are better for full-height racks with side cable management.
  • Stay with Basic PDUs for devices that must never lose power due to a management controller failure; metered/switched PDUs add convenience but introduce a network-dependent component in the power path.

Specs

Input PlugNEMA 5-15P (15A/120V)
Outlet Count15 total (12 rear + 3 front)
PDU TypeBasic / unmanaged, no metering
Rack Form Factor1U horizontal, 19-inch EIA-310

Related searches

What to check before buying

  • Measure your rack's usable depth and confirm at least 1U of free horizontal space plus rear clearance for the input cord and outlet plugs.
  • Verify the wall or floor receptacle is NEMA 5-15R on a dedicated 15A breaker; shared circuits with motors or HVAC loads cause voltage sags that upset IT equipment.
  • Count total device plugs: the AP9562 provides 15 outlets, so ensure you are not leaving critical gear unpowered—order a second PDU or a 20-outlet model if your device count approaches 15.
  • Check that your rack uses standard 19-inch EIA-310 mounting rails; APC Basic PDUs include brackets for square-hole and threaded-hole racks, but non-standard cabinets may need a adapter kit.

FAQ